CIP System

 

The CIP SYSTEM can cleaning equipments of blending system automatically, from start until to the end of cleaning work, all jobs are done by the control system automatic performance which function had been set in advance, the operator only makes the switching operation, all blending system equipment will be cleaned fast and simply.

CIP Equipment

  • CIP plate heat exchanger
  • Liquid store tank
  • Acidity, alkalescent liquid PH value mensuration machine
  • Acidity, alkalescent liquid dose pump
  • CIP infeed pump
  • CIP liquid reclaim pump
  • CIP infeed &reclaim pipeline
  • Automatic pneumatic valve

CIP 設備

 

CIP Cleaning Process

CIP

  • Water wash (water wash leftover)
  • Lye wash (lye cycle)
    Lotion: lye, specialty clean lotion
    Consistency: 1~2%
    Temperature: 70~90℃
  • Acidity Liquid wash
    Lotion: nitric acid, specialty clean lotion
    Consistency: 0.5~1.5%
    Temperature: 60~80℃
  • Pasteurizer
    Lotion: water
    Temperature: 90~95℃
     

CIP Cleaning Characteristics

  • Before cleaning process, setting target subject & checking, to avoid mistake of choosing
  • CIP liquid store tank automatic liquid-level inspection and complementarily
  • Acidity liquid, Lye automatic adding inspection
  • Heat up temperature and circumfluence temperature controller
  • All of automatic valve and pump start and stop controller
  • Running statues display
  • Failure automatic pause and warning

CIP清洗

 

Inquiry Form

.